FU-SUN-120/125/130/135/136-G01P3-EU-AM8 | 120-136kW | Three Phase | 8 MPPT

Higher yields / Safe & Reliable / Smart / User-friendly

Smart Monitoring Platform

Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier.

  • 8 MPP trackers, Max. effiffifficiency up to 98.8%
  • Zero export application, VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range
  • Anti-PID function (Optional)
  • Type II DC/AC SPD
ModelSUN-120K-G01P3SUN-125K-G01P3SUN-130K-G01P3SUN-135K-G01P3SUN-136K-G01P3
PV String Input Date 
Max. PV Input Power(kW)180187.5195202.5204
Max. PV Input Voltage(V)1100
Start-up Voltage(V)250
MPPT voltage range(V)200-1000
Rated PV Input voltage(V)600
Max. Input Short Circuit Current (A)60+60+60+60+60+60+60+60
Max. Operating PV Input Current(A)40+40+40+40+40+40+40+40
No. of MPP Trackers/No. of Strings per MPP Tracker8/4+4+4+4+4+4+4+4
AC Input/Output Side 
Rated AC Output Active Power(kW)120125130135136
Max. AC Output Apparent Power(kVA)132135135135136
Rated AC output current (A)181.9/174189.4/181.2197/188.5204.6/195.7206.1/197.2
Max. AC Output Current(A)200/191.4204.6/195.7204.6/195.7204.6/195.7206.1/197.2
Rated output voltage/range (V)
220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form3L+N+PE
Rated Output Grid Frequency/range(Hz)50Hz/45Hz-55Hz   60Hz/55Hz-65Hz
Power Factor Adjustment Range0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi<3%
DC Injection Current<0.5%ln
Efficiency 
Max. Efficiency98.8%
Euro Efficiency98.2%
MPPT Efficiency>99%
Equipment Protection 
DC Polarity Reverse Connection ProtectionYES
AC Output Overcurrent ProtectionYES
AC Output Overvoltage ProtectionYES
AC Output Short Circuit ProtectionYES
Thermal ProtectionYES
DC Terminal Insulation Impedance MonitoringYES
DC Component MonitoringYES
Ground Fault Current MonitoringYES
Power Network MonitoringYES
Island Protection MonitoringYES
Earth Fault DetectionYES
DC Input SwitchYES
Overvoltage Load Drop ProtectionYES
Residual Current (RCD) DetectionYES
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface 
Communication InterfaceRS485/RS232
Monitor Mode
GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data 
Operating Temperature Range (°C)‘-25 to +60℃, >45℃ Derating
Permissible Ambient Humidity0~100%
Permissible Altitude (m)4000m
Noise (dB)≤ 65 dB(A)
Ingress Protection(IP) RatingIP 65
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC),OVC III(AC)
Cabinet Size (WxHxD mm)1006mm*516mm*325.5mm(Excluding connectors and brackets)
Weight [kg]103
Warranty [year]5 years
Type Of CoolingIntelligent air cooling
Grid RegulationIEC 61727,IEC 62116,CEI 0-21,CEI 0-16,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2